logo
Shenzhen Wisdomshow Technology Co.,ltd
পণ্য
ব্লগ
বাড়ি > ব্লগ >
Company Blog About Minxray HPF40 Sets New Standard for Portable Veterinary Radiography
ঘটনা
যোগাযোগ
যোগাযোগ: Ms. Elysia
ফ্যাক্স: 86-0755-2733-6216
এখনই যোগাযোগ করুন
আমাদের মেইল করুন

Minxray HPF40 Sets New Standard for Portable Veterinary Radiography

2026-10-26
Latest company news about Minxray HPF40 Sets New Standard for Portable Veterinary Radiography

MinXray has introduced the HPF40, a portable X-ray unit built around high-frequency, full-wave rectification and a markedly reduced chassis weight. The company positions the device for veterinary clinicians and field teams that require diagnostic-quality imaging where line power is unpredictable and mobility is essential.

The unit weighs 6.6 kilograms and pairs a compact housing with a generator designed to hold output steady regardless of voltage fluctuation. MinXray says the combination is intended to serve both equine practitioners working outdoors and clinics integrating digital radiography into existing workflows.

High-frequency design raises output performance

Conventional self-rectified, line-frequency generators are constrained by comparatively low energy efficiency, a limitation that typically translates into a larger, heavier housing for a given output. MinXray's HPF40 instead uses high-frequency full-wave rectification, which the company says delivers a substantially better efficiency ratio than conventional equipment.

That architecture serves two purposes at once. It reduces overall weight, making the unit practical to carry between sites, and it maintains stable radiation output under demanding conditions. For equine clinicians in particular, the design is intended to insulate exposure from fluctuations in line voltage, preserving consistency from one image to the next.

Core technical features

The HPF40 incorporates a design MinXray markets as HighBurst, which shortens exposure times. Shorter exposures matter most with patients that cannot be relied upon to remain still, since reducing the interval during which motion can occur limits the likelihood of artifact on the final image.

The device also supports five preset exposure techniques, a feature intended to simplify operation and reduce the number of manual adjustments required during a clinical session. MinXray says the presets shorten setup time and improve throughput in settings where examinations are performed in sequence.

Specification Detail
Weight 14.5 lbs (6.6 kg)
X-ray output 70 kVDC; 10 mA / 2.0 s; 50 mA / 2.0 s
Power input 120 V (50/60 Hz)
Focal spot size 0.8 mm
Anode heat capacity 10 kHu
Total filtration 3.0 mm Al equivalent
Clinical use and compatibility

The HPF40 was designed as an imaging tool for professional veterinary use, with portability and reliability treated as the primary requirements. Its housing measures 7-1/4 inches wide by 12-1/4 inches long by 6 inches high, dimensions intended to make transport and positioning straightforward in confined spaces.

The unit is described as fully compatible with digital imaging systems of the kind already installed in many practices, allowing it to be incorporated into an existing digital workflow without replacement of the receptor or processing chain. An automatic dynamic line voltage adjustment function supports output independent of supply fluctuations.

Frequently Asked Questions
Is the MinXray HPF40 compatible with all digital imaging systems?
Yes. The device is designed to work with digital imaging systems generally, and users can integrate it into an existing digital imaging workflow according to clinical requirements.
What advantage does the HighBurst design offer in practice?
Its principal benefit is a shortened exposure time. This is especially relevant for animal patients that have difficulty remaining still, since fewer motion artifacts produce a clearer image.
How does the unit handle voltage fluctuation during field use?
The HPF40 includes automatic dynamic line voltage adjustment. Its output power is independent of fluctuations in the supply, so image quality remains consistent in field settings or where electrical service is unstable.